AWS E71T-1C Flux Core Welding Wire E501 0.04 / 0.045 / 0.052 / 0.0625 (1/16) In
Contact Person : Kevin Yin
WhatsApp : +8613812837333
Minimum Order Quantity : | one pallet | Price : | USD 1 |
---|---|---|---|
Packaging Details : | Neutral box/ LT color box/OEM brand box | Delivery Time : | 15 WORKING DAYS |
Supply Ability : | 1,200,000 TON PER YEAR |
Place of Origin: | CHINA | Brand Name: | LONGTENG |
---|---|---|---|
Certification: | TUV CE, ABS, DB, ISO9001:2015 | Model Number: | E71T-C1A4-Ni1 |
Detail Information |
|||
Product Name: | Gas Shielded Flux Cored Arc Welding Wire E71T-C1A4-Ni1 | Model: | E71T-C1A4-Ni1 |
---|---|---|---|
Brand: | LONGTENG | Diameter: | 0.04/0.045/0.052/0.0625(1/16) In |
Weight: | 2/11/33/44 Lb | Surface: | Silvery |
Spool Material: | Black/White Plastic Spool | Packing: | Color Box |
OEM: | Accept | Diameter Of Spool: | 100/200/270/300mm |
High Light: | 0.052 Flux Cored Arc Welding Wire,Gmaw Flux Cored Welding Wire |
Product Description
E71T-C1A4-Ni1 Flux Cored Arc Welding Wire 2/11/33/44 lb
LT·E501Ni
Conform to Standard :GB/T 17493 E491T1-Ni1C
AWS A5.36 E71T1-C1A4-Ni1, JIS Z3313 T493T1-1CA-N2
ISO 17632-B-T493T1-1CA-N2
Specification:
E71T1-C1A4-Ni1 is an all-position, flux cored welding wire intended for single and multiple pass welding of low-alloy and carbon steel where a minimum 70 kpsi tensile strength and good notch toughness is required. It is an excellent general purpose welding wire
Purpose:
Most widely used for welding some key structures like shipbuilding, mechanical manufacture, pressure vessels, boilers, petroleum machinery, chemical machinery, hoisting machinery etc.
Chemical Composition(%)(Shielding Gas:CO2)
Chemical Composition | C | Mn | Si | S | P | Ni | Cr | Mo | V |
Guarantee Value |
≤ 0.12 |
≤ 1.50 |
≤ 0.80 |
≤0.030 | ≤0.030 |
0.80~ 1.10 |
≤ 0.15 |
≤ 0.35 |
≤ 0.05 |
General Result | 0.04 | 1.28 | 0.38 | 0.006 | 0.011 | 0.90 | - | - | - |
Mechanical Properties of Deposited Metal(Shielding Gas:CO2)
Test Item | Rm(MPa) | ReL/Rp0.2(MPa) | A(%) |
KV2(J) -30℃ -40℃ |
|
Guarantee Value | 490~620 | ≥400 | ≥20 | ≥27 | - |
General Result | 570 | 510 | 27 | 135 | 120 |
Diffusion hydrogen content of the deposited metal (Mercury Method)≤10ml/100g
Reference Current(DC+)
Size(mm) | Φ1.2 | Φ1.4 | Φ1.6 | |
Current Range (A) | Flat Position | 120~300 | 150~400 | 180~450 |
Vertical Upward welding/ Overhead position | 120~260 | 150~270 | 180~280 | |
Vertical Downward weldingOverhead position | 200~300 | 220~300 | 250~300 | |
Horizontal Welding | 120~280 | 150~320 | 180~350 |
Notes:
1.Adopt degreasing and rust cleaning process before operate.
2.Shielding gas flow: 20-25L/min when welding
3.Extension: 15-25mm
4.The humidity of welding wire storage should be less than 60%
5.Storage period: Vacuum packaging less than 1 Year, other packaging less than half year.
Enter Your Message